ICR803 Bar Code Manual – Rev A – 04/2007 - 12 -
Presentation Mode
This programs the imager to work in Presentation mode. The LEDs are either off or at the lowest power for
ambient conditions until a bar code is presented to the imager. Then the LEDs turn on automatically to read
the code. Presentation Mode uses ambient light to detect the bar codes. If the light level in the room is not
high enough, Presentation Mode may not work properly.
Presentation LED Behavior after Decode
When an imager is in presentation mode, the LEDs remain on and continue scanning for a short time after a
bar code is decoded. If you wish to turn the LEDs off immediately after a bar code is decoded, scan the
LEDs Off bar code, below. Default = LEDs On.
* LEDs On
LEDs Off
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the imager's reaction time to bar
code presentation. To set the sensitivity, scan the Sensitivity bar code, then scan the degree of sensitivity
(from 0-20) from the inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least
sensitive. Default = 1.
Sensitivity
Hands Free Time Out
The Scan Stand and Presentation Modes are referred to as “hands free” modes. If the imager’s
trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You
can set the time the imager should remain in manual trigger mode by setting the Hands Free Time
Out. Once the time out value is reached, (if there have been no further trigger pulls) the imager
reverts to the original hands free mode.
Scan the Hands Free Time Out bar code, then scan the time out duration (from 0-300,000
milliseconds) from Appendix D, and Save. Default = 5,000 ms.