Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-27
Operation
A2. Tracking mode (controlled by Increment)
Max. 10 consecutive objects in conveyor direction simultanously in the reading field,
reading one side with internal object tracking
Conditions:
Minimum object gap between two objects in conveyor direction: 50 mm (1.97 in)
Size of reading field = distance between sensor for beginning/end of object and object
release point parameterized (data output)
Autofocus mode "Differential background and tracking“, see Table 6-6, Page 6-13 or
event-controlled focus position switchover
Incremental encoder connected to "IN 4" switching input
Possible reading triggers:
One external sensor (e. g. photoelectric reflex switch)
Command strings
Further preparations:
¾ Configuring reading area: see Chapter a)Parameterizing reading area, Page 6-10.
¾ Selecting focus control mode: see Chapter b) Selecting focus control mode,
Page 6-11.
¾ Configuring focus control: see Chapter c) Parameterizing focus control, Page 6-12.
¾ Configuring oscillating mirror (optional): see Chapter e) Parameterizing oscillation mirror
functions (optional), Page 6-17.
¾ Configuring no. of bar codes to be read: see Chapter h) Parameterizing the evaluation
characteristics, Page 6-36
Note To separate bar codes of the same type with identical contents, connect an incremental
encoder and activate the "Seperate codes dependent on reading angle" function. See also
Table 6-24, Page 6-36.
Activating and parameterizing internal object tracking:
Action Settings in CLV-Setup
1. Parameterize internal object
tracking
Ö DEVICE CONFIGURATION tab
Ö INTERNAL TRACKING Section
–active
Ö DISTANCE PER ENCODER PULSE Section
Value: according to encoder resolution
Ö TRACKING PARAMETERS button
Ö RELEASE POINTS Section
Focus release point
Object release point/End of reading field/Output data
Ö LABEL ASSIGNMENT TOLERANCE Section
Automatic (default setting) or
Fix Tolerance: value
Ö READING CONFIGURATION tab
Ö AUTOFOCUS PARAMETERS button
Ö AUTOFOCUS PARAMETERS tab
–C
ODE BASED FOCUS RELEASE IF... Section
Number of codes equals Minimum or
Number of codes equals Maximum or
Number of codes exeeds Maximum
Table 6-12: Guide: Parameterzing internal object tracking