Chapter 6 Operating Instructions
CLV490 Bar Code Scanner
6-38 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Operation
6.5 Operating modes and outputing the reading result
The following CLV490 operating modes/functions (and more) can be selected in CLV-Setup:
Standard operating mode:
Reading mode
For setup:
Percentage evaluation
Adjusting mode
For adapting the device to the application at hand:
Configuring (parameterizing) the CLV490.
See Chapter 6.4.1 Configuring the CLV490 via the user interface of CLV-Setup,
Page 6-5
Background teach-in
Show background
Show RA-limits
For monitoring purposes/trouble shooting:
Background analysis
I/O monitor in incremental pulse
Display and edit operating data
Reading diagnosis
Monitor host interface
Auxiliary input
Self-test
6.5.1 Reading mode (standard operating mode)
The CLV490 performs a self-test after it has been switched on. It switches to Reading mode
("Device Ready" LED lights up). In the default setting the "Sensor" switching input is the
(external) trigger source of the reading pulse. The reading result is output by the CLV490 at
the end of the reading pulse via the host interface (default setting) and auxiliary interface.
Depending of the configuration, the "Result 1" to "Result 4" switching outputs become live
for the predefined pulse length when defined events occur during the reading process (e. g.
Good Read).
The reading result of the auxiliary interface can be displayed in the CLV-Setup Terminal
Emulator. The CLV490 auxiliary interface must be set to the Reading Diagnosis mode for
this purpose. This mode is selected for the default setting. The reading result of the auxiliary
interface has a fixed, invariable format.
The Reading mode can be called up by choosing V
IEW in the menu bar or via the Terminal
Emulator.
Line scanner with oscillating mirror:
In the Reading mode the CLV490 deflects (by default) the scan line about the position
CW = 50 at a frequency of 1 Hz and a maximum angle of ±20°. 50 CW corresponds to an
angle of deflection of 105°.