Chapter 3 Operating Instructions
CLV490 Bar Code Scanner
3-2 © SICK AG · Division Auto Ident · Germany · All rights reserved 8009993/RA61/2007-07-20
Product description
3.1.3 System requirements for stand-alone configuration
CLV490 without heater The following are required to start up and operate the CLV490 without heater:
1. A SICK Connection Module to provide the power supply of the CLV490 (18 to 30 V DC)
and connect the data and function interfaces. Available types:
CDB420-001 (no. 1023885) for 10 to 30 V DC, enclosure rating max. IP 65
CDB420-101 (no. 1024305) for 10 to 30 V DC, enclosure rating max. IP 65
CDM490-0001 (no. 1025363) for 10 to 30 V DC, enclosure rating max. IP 65
– or –
Alternatively, a non-SICK Power pack with a voltage output of 18 to 30 V DC (functional
extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of 20 W.
Cable no. 2020264 (3 m (9.84 ft)) with 15-pin D Sub HD connector and one open end
for connecting the CLV490 to the non-SICK Power pack (supply voltage).
2. The following operating voltages/power output values:
CDB420-001: 18 to 30 V DC (to IEC 364-4-41), min. 20 W
CDM490-0001: 18 to 30 V DC (to IEC 364-4-41), min. 40 W,
when using the CMP490 Power Supply Module: 100 to 250 V AC, 50 to 60 Hz
If the following modules are additionally built-in in the CDB420:
CMC400 (Conenction Module Cloning): 18 to 30 V DC, additionally 0.5 W
If the following modules are additionally built-in in the CDM490:
CMC400 (Connection Module Cloning): 18 to 30 V DC, additionally 0.5 W
CMD400 (Connection Module Display): 18 to 30 V DC, additionally 1 W
CMF400 (Connection Module Fieldbus): 18 to 30 V DC, additionally 2 W
3. Fitting cables see Chapter 5.2.2 Prefabricated cables (overview), Page 5-2.
4. With external clock pulse (start/stop) supply via the "Sensor" switching input: a suitable
reading pulse sensor for signaling an object with a bar code, e. g. a photoelectric reflex
switch.
5. With extended external clock pulse (stop) via the "IN 4" switching input: a suitable read-
ing pulse sensor for signaling the end of an object, e. g. a photoelectric reflex switch.
6. With object distance detection via the "IN 0" to "IN 4" switching inputs: suitable sensors
for multi-stage dynamic focus control, e. g. photoelectric reflex switches.
7. With internal object tracking: a suitable incremental encoder, e. g. no. 2022714.
8. To separate bar codes with the same name (same code type, identical data content):
a suitable incremental encoder (s. above).
9. A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.
10. A PC (min. Pentium II, 350 MHz, 64 MB RAM, CD drive, a serial port (COM x), mouse
(recommended)) with Windows 95
TM
/98
TM
, Windows NT
TM
, Windows 2000
TM
or
Windows XP
TM
.
11. A 3-core RS 232 data cable (null modem cable) with two 9-pin D Sub sockets for con-
necting the PC to the auxiliary interface of the CLV490 in the connection module, e. g.
no. 2014054. Pin 2 (RxD) and Pin 3 (TxD) are crossed.
12. An HTML browser, e. g. Internet Explorer
TM
, for using the online help system CLV-Setup
Help.
13. To connect the CLV490 to Profibus DP, to Device Net or to Ethernet TCP/IP: the appro-
priate CMF400 Connection Module Fieldbus for building-in in the CDM490 Connection
Module.