10.13.4 Cables, external parameter memories and plug cover
a) CLV without heater
Temperature range of connection material:
Stationary: –30 ... +70
°
C; moving: 0 ... +70
°
C
Note Other cable lengths/types for CLV without heater available on request.
Order No. Description Wires Length Connection
2 020 302 Connection cable for data interfaces ("Host/Term") or function interfaces
("I/O"),
8 mm, shielded, with 15-pin D Sub HD socket and
15-pin D Sub HD plug.
Required: 2 per CLV
15 3 m CLV 490 to
AMV/S 60
AMV 30-071
BMV 10/BMS 20
2 020 303 Connection cable for data interfaces ("Host/Term"),
8 mm, shielded, with
15-pin D Sub HD socket and one open end (stripped).
Required: 1 per CLV
15 3 m CLV 490 to Host
2 020 264 Connection cable for function interfaces and power supply ( "I/O"),
8 mm, shielded, with 15-pin D Sub HD plug and one open end (stripped).
Required: 1 per CLV
15 3 m CLV 490 to sensors
PLC and non-SICK
Power pack
2 020 307 Connector cover with parameter memory (EEPROM),
enclosure rating IP 65, with two connection cables,each
8 mm, shielded,
with 15-pin D Sub HD socket and 15-pin D Sub HD plug.
Required: 1 per CLV
each 15 x
0.14 mm
2
3 m CLV 490 to
AMV/S 60
AMV 30-071
BMV 10
2 020 981 Connector cover with parameter memory (EEPROM),
enclosure rating IP 65, with two connection cables, each
8 mm, shielded,
two open ends (stripped).
Required: 1 per CLV
each 15 x
0.14 mm
2
3 m CLV 490 to host,
sensors, PLC and
non-SICK Power
pack
2 020 308 Connector cover with parameter memory (EEPROM),
enclosure rating IP 65, with two connection cables
8 mm each, shielded,
with 9-pin D Sub HD plug and one open end (stripped).
Required: 1 per CLV
each 10 x
0.2 mm
2
3 mm CLV 490 to
BMS 20
2 014 054 RS 232 data cable,
5 mm, shielded, with two 9-pin D Sub sockets
(Pin2 (RxD) and Pin 3 (TxD) crossed)
3 3 m PC to AMV/S
BMV 10/BMS 20
6 010 088 Data cable,
6.6 mm, shielded, for connection cables up to 3 m 15 x 0.09
mm
2
Meter
ware
Free wiring
6 007 508 Data cable,
8.5 mm, twisted pair, shielded 2 x 2 x
0.23 mm
2
Meter
ware
SICK network
(RS 485)
Table 10-14: Accessories: cables and connector covers for the CLV without heater