Chapter 6 Operating Instructions
CLV 490 Bar Code Scanner
6-12
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Operation
Parameterization oscillating mirror functions:
Action Line scanner with oscillating mirror
1. Choose "Oscillating with fixed amplitude"
mode
(identical amplitude for all distance configura-
tions with event-controlled focus control)
– or –
O
SCILLATING
M
IRROR
tab
O
SCILLATING
M
IRROR
– Oscillating with fixed amplitude
O
SCILLATING
– Frequency
2. Choose "Oscillating with variable amplitude"
mode
(amplitude can be chosen for each distance
configuration with event-controlled focus
control)
– or –
O
SCILLATING
M
IRROR
tab
O
SCILLATING
M
IRROR
– Oscillating with variable amplitude
O
SCILLATING
– Frequency
R
EADING
C
ONFIGURATION
tab
E
DIT
A
UTOFOCUS
respectively
Distance Configurations
– Oscillating Mirror Amplitude
3. Choose "Fixed Position" mode
– or –
O
SCILLATING
M
IRROR
tab
O
SCILLATING
M
IRROR
– Fixed Position
F
IXED
P
OSITION
– Stationary Position (CW)
4.
Choose "One-Shot" mode O
SCILLATING
M
IRROR
tab
O
SCILLATING
M
IRROR
– One-Shot
O
NE
-S
HOT
P
HASE
1
–Mirror Speed
– Start Position
– Distance Configuration (no.)
P
HASE
2
–Mirror Speed
– Start Position
– DistanceConfiguration (no.)
5. With One-Shot: choose trigger source
O
SCILLATING
M
IRROR
tab
O
NE
-S
HOT
T
RIGGER
M
ODE
– Reading Trigger Pulse or
– "IN 3" switching input or
– "IN 4" switching input or
– Serial Interface
6. With One-Shot and trigger source "IN 3" or
"IN 4":
Choose function for switching input "IN 3" or
"IN 4"
D
EVICE
C
ONFIGURATION
tab
A
SSIGNMENT
IN 3
– One Shot or
A
SSIGNMENT
IN 4
– One Shot
see also Table5-21, Page5-19
7. Choose activity of oscillating mode
O
SCILLATING
M
IRROR
tab
O
SCILLATING
M
IRROR
acitve
– continuous
– during reading interval
Table 6-7: Guide: Parameterizing oscillating mirror functions